Digital X-ray Image Acquisition System
- Digital Detector Trixell Pixium® 4600 - CsI:Tl/a-Si
- 43x43 cm (17x17 inch) active area
- 143 µm pixel pitch
- 3.5 cycles/mm detector Nyquist frequency
- DQE
>55% @ 1.0 cycles/mm
>45% @ 2.0 cycles/mm
>25% @ 3.0 cycles/mm
- 14-bit dynamic range

Operator Console
- Controls detector and X-ray generator
- Patient demographics via keyboard or HIS/RIS
- Anatomically Programmed Radiography (APR)
- Automatic Exposure Control (AEC)
- Automatic collimator remote control
- DICOM 3.0 compliant
- Processing algorithms (exam-specific)
- Print layout film editor
- 18-inch high resolution TFT LCD

Fully Automated Digital Radiography System
Ceiling mounted X-ray tube suspension
- Minimum focal spot/ceiling distance: 93 cm (36.6 inch)
- Focal spot/telescopic axis distance: 35 cm (13.8 inch)
- Exploitation area: 437x295 cm (172.0x116.1 inch)
- Vertical movement speed: 8 cm/s (3.1 inch/s)
- Tube vertical travel: 160 cm (63.0 inch)
- Tube rotation around telescopic axis: 360°
- Tube rotation around horizontal axis: +/- 115°
- Longitudinal, lateral and vertical brake: negative - 24 Vdc
- Tube rotation brake: negative -24 Vdc
- FFD, tube rotation angle data on display
- Automatic collimator with remote control
- Automatic source detector alignment
- Electrical power: 115/230 VAC, single phase
- Max power required: 700 VA
- Weight: 350 Kg (771.6 lbs)
- Typical room ceiling height: 280 cm (110 inch)
Radiographic table
- Patient positioning area: 230x55 cm (90.5x21.6 inch)
- Table lateral travel: +/- 13 cm (5.1 inch)
- Table structure: carbon fibre
- Absorption: < 0,9 mm/Al equivalent
- Lateral shift electromagnetic brakes: -24 Vdc
- Table rotation electromagnetic brakes: -24 Vdc
- Table minimum height: 58.5 cm (23.0 inch)
- Table maximum height: 80.5 cm (31.7 inch)
- Table vertical shift: 22 cm (8.7 inch)
- Vertical speed: 1.5 cm/s (0.6 inch/s)
- Table rotation: 90° manual
- Max. patient weight (IEC 601-1): 180 kg (396.8 lbs)
- Weight: 300 kg (661.4 lbs)
- Overall dimensions (cm): L: 230; W: 670; H: 590.
(inch): L: 90.5; W: 263.8; H: 232.3
Digital detector positioning device
- Exploitation area: 170x43 cm (66.9x16.9 inch)
- Longitudinal shift: 219 cm (86.2 inch)
- Longitudinal shift electromagnetic brakes: -24 Vdc
- Max. longitudinal speed: 40 cm/s (15.7 inch/s)
- Digital detector rotation: -15°; +90° motorized
- Detector rotation speed: 15°/s
- Tube rotation angle: available on digital display
- Max. error on tube angle rotation: +/- 1°
- Vertical detector shift: motorized and manual
- Detector vertical shift: 121 cm (47.6 inch)
- Max. detector vertical speed: 3 cm/s (1.2 inch/s)
- Detector centre max. distance to floor: 157 cm (61.8 inch)
- Detector centre min. distance to floor: 36 cm (14.2 inch)
- Propietory antiscattering device
- Weight: 300 kg (661.4 lbs)
- Overall dimensions (cm): L: 271; H: 240; W; 100
(inch): L: 106.7; H: 94.5; W: 39.4
- Electrical power: 110/220 VAC, single phase
- Max power required: 2,500 VA

X-ray Tube
- 32/72 kW (1)
- Exposure voltage: 40-150 kVp
- Maximum anode heat content: 350 kHU
- Focal spots: 0,6-1,0 mm
- Anode rotation speed: 9000 rpm

X-ray Generator
- 65 kW high frequency (100 kHz) output (2)
- 40-150 kVp
- Dual speed starter
- mAs range: 0.5-1,000 mAs
- Digital interface
- 400 VAC, 480 VAC, 3 phase

Optional Components
- Automatic Operator Log-In
- Laser Printer Interface
- X-ray generator control console
- Patient stand stretcher and grip
- Digital Keypad
- BAR code reader
- CD-R

 
 
 
 


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note (1): Available on request: 30-100 kW; focal spots 0,6-1,2 mm; 400 kHU.

Note (2):
Available on request 80 kW high frequency generator.

For further details
download the brochure >>

 

   
 
 
 